Main Operating Loading Firing Adjustments Safety

Cocking








Filling Instructions
NOTE! Only use clean, filtered and dry compressed air. Over Pressurisation will damage teh cylinder beyond repair!


Warning note concerning 300 Bar bottles
With the advent of the 300 bar bottle it should be noted that more care needs to be taken when filling your rifle. The filling procedure described in this manual must be followed, particularly the slow opening of the valve on the bottle. Opening the valve quickly and/or allowing the filling bottle and cylinder to equalise to greater than 190bar could result in serious personal injury to yourself or any bystander and/or irreparable damage to the cylinder.

The S400 has a pressure indicator mounted under the stock fore end. This provides a visual check on the amount of remaining air in the cylinder. There are two types of gauge that may be fitted. One has colour graduations and the other has numeric. In both cases, the graduation indicates 0 to 250 bar. DO NOT fill to the required pressure by watching this indicator. The needle reaction speed has been slowed to prevent damage while filling and takes time to synchronise to the actual pressure in the cylinder.
In the interests of safety the rifle cylinder has a blow-out device that operates at approximately 250 bar. Once operated (Indicated by deformation of the cylinder end) the cylinder is beyond further use and must be replaced.

Filling Pressures:
4.5mm/.177 cal 200 BAR
5.5mm/.22 cal 200 BAR
NOTE! Filling to higher pressures will NOT increase power and may prevent operation completely or cause cylinder damage. Filling to lower pressures will not reduce power, only the number of shots.